MULTI SERIES MOBILE X-RAY SYSTEMS.
Category: MOBILE X-RAY SYSTEM
MULTI 32 A / 32 D / 40 A / 40 D Series
The system can be used in both adult and pediatric patients for general diagnostic radiographic imaging, including evaluation of musculoskeletal injuries, thoracic imaging, trauma assessment, and orthopedic conditions.
With its ability to provide fast and efficient imaging, the system supports timely clinical decision-making.
The device must be operated exclusively by authorized healthcare professionals and in accordance with applicable radiation safety protocols.
Model |
MULTI 32-A Series Mobile X-Ray Systems |
MULTI 32-D Series Mobile X-Ray Systems |
MULTI 40-A Series Mobile X-Ray Systems |
MULTI 40-D Series Mobile X-Ray Systems |
General Features |
40 kHz - H.F. 32 kW - 125kV - 500mA - 320mAs - APR |
40 kHz - H.F. 32 kW - 125kV - 500mA - 320mAs - APR |
40 kHz - H.F. 40 kW - 125kV - 600mA - 320mAs - APR |
40 kHz - H.F. 40 kW - 125kV - 600mA - 320mAs - APR |
kV Value |
40-125 kV in 1 kV steps |
40-125 kV in 1 kV steps |
40-125 kV in 1 kV steps |
40-125 kV in 1 kV steps |
mA Value |
In 10-500mA steps |
In 10-500mA steps |
In 10-600mA steps |
In 10-600mA steps |
mAs Value |
In steps of 0.2-320 mAs |
In steps of 0.2-320 mAs |
In steps of 0.2-320 mAs |
In steps of 0.2-320 mAs |
Time Value |
In steps of 0.001-3.2 sec |
In steps of 0.001-3.2 sec |
In steps of 0.001-3.2 sec |
In steps of 0.001-3.2 sec |
Seal Sizes |
Seal sizes: 0.6 x 1.3 mm |
Seal sizes: 0.6 x 1.3 mm |
Seal sizes: 0.6 x 1.2 mm |
Seal sizes: 0.6 x 1.2 mm |
Anode Heat Capacity |
Anode Heat Capacity: 110 kHU |
Anode Heat Capacity: 110 kHU |
Anode Heat Capacity: 300 kHU |
Anode Heat Capacity: 300 kHU |
Hoube Heat Capacity |
Haube Heat Capacity: 1100 kHU |
Haube Heat Capacity: 1100 kHU |
Haube Heat Capacity: 1250 kHU |
Haube Heat Capacity: 1250 kHU |
Flat Panel Detector |
N/A |
35x43 cm - 2500x3000 pixels - 140 mm - 16 bit - Wireless - 3 kg |
N/A |
35x43 cm - 2500x3000 pixels - 140 mm - 16 bit - Wireless - 3 kg |
Usage and Driving |
10 km motorized |
10 km motorized |
10 km motorized |
10 km motorized |
Battery Shooting Feature |
300 shots with battery |
300 shots with battery |
300 shots with battery |
300 shots with battery |
Horizontal rotation of the tube |
+/-210 Degree Vertical Tube Rotation |
+/-210 Degree Vertical Tube Rotation |
+/-210 degree Vertical Tube Rotation |
+/-210 degree Vertical Tube Rotation |
Vertical Rotation of the Tube |
+/-90 Degree Rotation Tube |
+/-90 Degree Rotation Tube |
+/-90 Degree Rotation Tube |
+/-90 Degree Rotation Tube |
Vertical Rotation of the Tube Statif |
+/-90 degree rotation of the Tube Statif vertically |
+/-90 degree rotation of the Tube Statif vertically |
+/-90 degree rotation of the Tube Statif vertically |
+/-90 degree rotation of the Tube Statif vertically |
Control Panel (For Analog System) |
Touch Screen Control Panel |
N/A |
Touch Screen Control Panel |
N/A |
Workstation and Image Processing Software |
N/A |
19" touchscreen computer |
N/A |
19" touchscreen computer |
Collimator Type |
Manual Control |
Manual Control |
Manual Control |
Manual Control |
Lighting Feature |
With LED light and timer |
With LED light and timer |
With LED light and timer |
With LED light and timer |
Weight |
~450 kg |
~470 kg |
~450 kg |
~480 kg |